Evaluation of ultrafiltration membrane combination process in Nanjiao Waterworks

Ji Hongjie,Gao Wei,Chang Haiqing,Liang Heng,Tian Xibin,Guo Ailing,Li Guibai,Shen Qiuchang
DOI: https://doi.org/10.3969/j.issn.1673-9353.2011.03.001
2011-01-01
Abstract:Application of UF as the key technology of water quality improving project in Nanjiao Waterworks with a water supply capacity of 10×104 m3/d was analyzed and evaluated for one year.The practical operation indicated that the effluent water quality was largely improved by UF combination process,and the effluent turbidity of UF was kept below 0.02 NTU.The average removal rates of CODMn,UV254 and TOC by UF combination process were(44.96±3.69)%,(43.22±2.21)% and(20.10±1.51)% respectively,which were improved 8.99,10.23 and 7.81 percent points comparing with sand filtration process.Meanwhile,the removal efficiencies of algae and pathogenic microorganism were prominent.The water quality could fully satisfy the requirement of the Standards for Drinking Water Quality(GB 5749-2006).The conventional process as a pretreatment could retard the synergies of membrane,coagulation,sedimentation,sand filtration and dosing powdered activated carbon(PAC).It could effectively ensure the stability of UF membrane operation in a sustainable flux.The domestic UF membrane had satisfied water production efficiency and anti-contamination ability.The water cleaning could control the increase of trans-membrane pressure(TMP)effectively,and extend the recoverable chemical cleaning period.The actual investment and operational cost of the UF combination process were lower than the estimated value.
What problem does this paper attempt to address?