Treatment of Effluent from Sedimentation Tank of Waterworks by Ultrafiltration Membrane

Yu JIANG,Ping GU,Hai-yan WANG,Feng-hua HE,Tao HAN
DOI: https://doi.org/10.3969/j.issn.1000-4602.2012.05.011
2012-01-01
Abstract:A pilot-scale internal pressure ultrafiltration(UF) membrane system was used to treat effluent from sedimentation tank in a waterworks and the quality of produced water from UF membrane system was investigated for a long time.The results demonstrated that a high removal rate of turbidity was achieved in different water quality periods,with an average removal rate of 93.4%.The guarantee rate of turbidity below 0.1 NTU was 99.4%.The removal efficiency of UF membrane system was significantly better than that of conventional filter process.The removal efficiency of organic matters in the effluent from sedimentation tank by UF membrane system was limited.The average removal rates of CODMn and UV254 were 17.2% and 8.2%,respectively.The guarantee rate of CODMn≤2 mg/L was above 98%.The CODMn concentration in membrane effluent was little influenced by the influent quality and the operation condition.Organics with low molecular weight were dominant in membrane influent.DOC and UV254 with MW of less than 1 ku accounted for 57.3% and 53.5% of the total organics.Microorganisms could be effectively removed by UF membrane system,and the membrane effluent quality could meet the hygiene requirements without disinfection,which reduced the chlorine dosage for subsequent disinfection and the formation of disinfection byproducts.
What problem does this paper attempt to address?