The Research of Missile Temperature Acquisition System Based on a Platinum Resistance

ZHU Jie,GUO Tao
DOI: https://doi.org/10.3969/j.issn.1671-1815.2013.09.042
2013-01-01
Abstract:In order to improve the missile temperature measurement precision,a kind of multi-point acquisition temperature sensor based on a platinum resistance was put forward.Constant current source was used to reduced power consumption of precision platinum,the temperature drift was reduced by four wire system and symmetric assembled data amplifier circuit.The signal was filtered by five order low-pass filter MAX280,was put to A/D conversion,and was connected through X9241.AT89S52 controlled to adjust the output of the zero drift,the least square method was used in the segmented range.Experiments show that the temperature error is less than 0.05 ℃ between the temperature range of-50 ℃~400 ℃.At present,the circirt as the core temperature measurement and control system has been used in a missile system.