Valve leak testing and leakage rate calibration based on acoustic emission

Wang Guanglin,Yan Xintao,Liu Jun
DOI: https://doi.org/10.3969/j.issn.1671-3133.2012.04.027
2012-01-01
Abstract:A valve leakage rate measurement system was built using Acoustic Emission(AE)method based on the principle of valve leakage generating AE signals,which could be used to test valve leakage lower than 0.1Pa·m3/s,and used air bubble method to calibrate the system.For the signal detection problem of susceptible to environmental noise,the conditional circuit was designed to reduce the effect of noise,and a LabVIEW program was compiled to analyze and process the capturing AE signals.In the established system,a manual ball valve was used as measured object and a large number of experimental results showed that the system could make qualitative analysis quickly and easily for tiny leak on the valve.
What problem does this paper attempt to address?