Ferromagnetic Tubes Testing Based Pulsed Remote Field Eddy Current Technique

YANG Li-jian,WANG Geng,GAO Song-wei
DOI: https://doi.org/10.3969/j.issn.1002-1841.2012.11.048
2012-01-01
Abstract:In view of the traditional remote field eddy current technique for ferromagnetic tube having the same sensitivity of inner and outside walls defect,unable to distinguish the defects in the inner wall or in the outer surface,this paper adopt with abundant frequency components of the pulse signal to replace the traditional remote field eddy current sinusoidal excitation signal.Using the methods of wavelet denoising to filter acquired signal and process the data.This paper studied the relationship between the tube wall defects and signal time-domain characteristics when the detector coil was placed in the direct zone,transition zone and remote field zone.Conduct experiments to acquire data about different depth defects in the inside or outside of the walls,the results show that using the pulse signal as excitation source and characteristics about the detect signal amplitude and zero-crossing time can effectively distinguish between the inner and outer circumferential direction tube wall defects.
What problem does this paper attempt to address?