Signal difference-based nondestructive low-frequency electromagnetic testing for ferromagnetic material pipe equipment

Jiao Yang,Zexu Liu,Xiang Li,Ruimeng Zhang,Yingqi Yang,Bin Zhu,Yang Liu,Zhouhong Zhu,Xufeng Jing,Jun Zhou,Jie Dong,Zhaokun Wang,Bin Fang,Changyu Shen
DOI: https://doi.org/10.1007/s13349-023-00694-5
2023-04-11
Journal of Civil Structural Health Monitoring
Abstract:Nondestructive testing for ferromagnetic material equipment based on low-frequency electromagnetic technique (LFET) and signal difference is proposed. Magnetic field distributions of the defect area in or on the 20# steel surfaces are analyzed using the finite element method (FEM) based on COMSOL Multiphysics. After the signal difference converting, for a surface defect in the 1.2 to 9.6 mm depth, amplitude voltage ranges of 1.8 to 4.2 V and 2.5 to 3.5 V are obtained for the defects in 20# steel plate and pipe, respectively. In addition, compared with the traditional MFL, the 4.8-mm buried internal depth and the 9.6-mm depth surface defect are detected in the 12-mm-thick 20# steel plate or pipe, which is about 1.6 times higher than that of the current similar sensors.
engineering, civil
What problem does this paper attempt to address?