Thermal & Structure Coupling Field Analysis of Fixed Tube-sheet Heat Exchanger based on ANSYS

ZHAO Jie,LI Feng,LIU Moujun
DOI: https://doi.org/10.3969/j.issn.1003-5311.2012.07.013
2012-01-01
Abstract:In this paper,a fixed tube-sheet heat exchanger that may exist with security risks was assessed in a Sinopec company.The general program for the heat exchanger was developed by using ANSYS parametric design language(APDL).It can be analyzed by the thermal structure coupled field in the indirect method.Respectively,the stress analysis data was obtained under the tube side pressure,shell pressure and thermal load that is in service conditions.According to JB4732-95 steel pressure vessels design by analysis to analyze and check the data,the results showed that all components of the heat exchanger meets the check conditions,and the safety margins are greater than 1.23.It provides the reference for the safety assessment of the heat exchanger in service.