Influence of Operating Regulation of Hot Blast Stove on Temperature Distribution of Regenerator in High Blast Temperature

陈杉杉,倪萍,国宏伟,张建良,杨天钧
DOI: https://doi.org/10.3969/j.issn.1000-7059.2012.03.011
2012-01-01
Abstract:With increasing blast temperature, distribution of temperature in regenerative chamber of hot blast stove will be changed correspondingly. Numerical simulation of temperature change of hot blast stove of Qiangang No. 2 blast furnace, Shougang Group, was done under high temperature and va- rious operations in the paper. As demonstrated by results ,the high temperature zone ( ≥ 1 573 K)of re- generative chamber is extended downward by 0.25 m with temperature increased by 10 K; the high temperature zone of regenerative chamber is extended downward by 0.83 m and output exhaust gas temperature is increased by 25 K with exhaust gas speed elevated by 1 m/s;the height of silica bricks should be lifted, heat capacity and heat conductivity checkered bricks in intermediate temperature zone should be strengthened in order to increase heat quantity and heat exchange efficiency under high tem- perature condition.
What problem does this paper attempt to address?