Measuring Technique of Nutrition Composition in Feed for Ruminant by Near Infrared Reflectance Spectroscopy(NIRS)

NIU Zhi-you,HAN Lu-jia
DOI: https://doi.org/10.13300/j.cnki.hnlkxb.2007.05.018
2007-01-01
Abstract:The 151 samples of feed for ruminant were collected.The use of near reflectance spectroscopy(NIRS) was investigated as an alternative method for predicting chemical composition.The NIRS calibration models were developed by using the partial least squares(PLS) technique.The coefficient of determination in calibration(R2) and standard error(RMSEC) of chemical analysis value and NIRS prediction value of calibration sets were 0.927 3 and 0.265,0.928 9 and 0.682,0.950 5 and 0.228,0.906 0 and 0.542,0.919 8 and 0.558 for moisture,crude protein,crude fat,crude ash,crud fibre,respectively.The coefficient of determination in calibration(r2) and standard error(RMSEP) of validation set were 0.920 6 and 0.284,0.919 4 and 0.690,0.926 4 and 0.312,0.943 4 and 0.437,0.903 5 and 0.616 for moisture,crude protein,crude fat,crude ash,crud fibre,respectively,and the RPD were all over 3.It was concluded that NIRS can be used as a method to monitor the chemical composition of feed for ruminant.
What problem does this paper attempt to address?