Quantitative Analysis of Fat Content in Brown Rice by Near Infrared Spectroscopy (NIRS) Technique

WANG Hai-lian,WAN Xiang-yuan,HU Pei-song,ZHAI Hu-qu,WAN Jian-min
DOI: https://doi.org/10.3321/j.issn:0578-1752.2005.08.006
2005-01-01
Abstract:Based on NIRS technique and partial least squares (PLS) algorithm, two calibration models were established tanalyze quantitatively fat content (FT) in brown rice grain and brown rice flour, respectively. The determination coefficients (R2) othese two models for FT were 94.44% and 95.54%, and the root mean square errors of cross validation (RMSECV) were 0.09% an0.08%, respectively. In external validation, the R2 value between the true value and predicted value were 79.51% and 87.10% for Fin brown rice grain and brown rice flour, and the root mean square errors of prediction (RMSEP) were 0.24% and 0.26%, and thaverage relative errors were 4.11% and 3.30%, respectively. These results indicated that the method of NIRS has relatively higaccuracy in prediction tests for FT in brown rice grain and brown rice flour and that the two mathematic models established in thpresent study should be useful for nutrient quality improvement in rice breeding program.