APPLICATION OF NEAR INFRARED REFLECTANCE SPECTROSCOPY (NIRS) TO ANALYSIS CRUDE PROTEIN IN GROUNDED RYE HAY

赵环环,胡跃高,赵其波,张鹏
DOI: https://doi.org/10.3969/j.issn.1006-267x.2001.04.008
2001-01-01
Abstract:forage rye samples with various species and maturity were collected from different fields in Wuqiao County,Hebei province,China and estimated the content of CP by chemical methods.30 samples were used to constitute the standard sample set and 21 samples were used to constitute the performance analysis sample set.The results of calibration sample set showed that the re-correlation coefficients(R2) between NIRS and chemical methods values were 0.99 for CP and the root square standard error of calibration(RMSEC) were 0.34%.The results of performance sample set showed that the re-correlation coefficients(R2) between NIRS and chemical methods values were 0.98 for CP and the root square standard error of prediction(RMSET) were 0.42%.NIRS technique can be used to estimated the content of CP in grounded rye hay with vrious species and maturity quickly,simply and accurately.
What problem does this paper attempt to address?