APPLICATON OF TURBINE-DRIVEN INDUCED DRAFT FAN FOR ULTRA-SUPER CRITICAL 1000 MW UNIT

MA Xiaolong,CHEN Shuping,LI Xuezhong,ZHANG Sheng,GAO Jinghui,SHOU Bing,YANG Bo,WU Gang
DOI: https://doi.org/10.3969/j.issn.1002-3364.2011.06.075
2011-01-01
Abstract:After merging the induced draft fan(IDF) of boiler with the booster air fan used for flue gas desulphurization of ultra-supercritical 1000 MW unit in one power plant,a small-turbine driven IDF has been adopted.The influence of turbine-driven IDF upon main operating indices of power plant has been analysed,results of analysis show that the adoptation of turbine driven large-capacity IDF can avoid impulse to the auxiliry electric system in start-up process of IDF,reducing substantially the consumption rate of service power.