Study on Control Technology of Self-Calibration for Seafloor Hydrothermal Fluid Ph Exploration Electrode

WU Huai-chao,JIN Bo,YANG Can-jun,ZHOU Yong,CHEN Ying
DOI: https://doi.org/10.3969/j.issn.1005-9865.2008.01.013
IF: 5
2008-01-01
Ocean Engineering
Abstract:In the course of seafloor hydrothermal fluid pH exploration,characteristics of exploration electrode will change with time.In order to implement long-time in-situ exploration,a set of fluid control system is needed to carry out the function of self-calibration and self-maintaining for exploration electrode.Aiming at the goal of the fluid control system,and considering its low power consumption design principle,a main control system is developed,covering hardware design and software development.To enable the control system to apply in seafloor hydrothermal fluid environment,pressure housing of the control system is designed,and pressure experiment is performed.The experiment results show that the system can work normally in 40MPa environment.The test data show that the system can implement automatically the function of self-calibration and self-maintaining for pH exploration electrode.
What problem does this paper attempt to address?