Software Regulate DC Component in Inverter Output Voltage Based on DSP

Ling-hui JIN,Zheng-yu L(U)
DOI: https://doi.org/10.3969/j.issn.1000-100X.2011.09.001
2011-01-01
Abstract:The DC component in output voltage is an adverse factor to inverter and its loads,so effective measures must be adopted to eliminate DC component for ensuring system operated reliably.Various reasons for producing DC component are analyzed,and the influence of reference sine wave for dual loop inverter are discussed,by comparing the advantages and disadvantages of hardware or software regulating DC bias,and two novel methods based on software are proposed.The operation principle and implementation measures of them are described.And operation of a 5 kW output power single phase full bridge inverter base on DSP TMS320F2812,the results show that two software mea-sures are both feasible that achieve the aim of regulating DC component,but the second measure is better in dy-namic performance in output voltage.
What problem does this paper attempt to address?