Treatment of Acrylic Acid Wastewater with Combining Coagulation and Fenton Process

赵静静,张明,张伟军
DOI: https://doi.org/10.3969/j.issn.1673-9655.2011.06.017
2011-01-01
Abstract:Treatment of less - biodegradable acrylic acid wastewater with combining coagulation and Fenton process was researched to find out the impacts on removal rate of COD. The results showed that the removal rate of the wastewater with high concentration of 150000 - 160000mg/L can reach 80% by the process. However, for the consideration of the actual production of cost, operation difficulty and sludge quantity, the optimal reaction of coagulation were that the dosage of 10% PAC was 5% with 0. 25% of 1‰ PAM, pH was 9, the reaction time was 5 minutes. The optimal reaction of Fenton were that initial pH was 3, and the mole rate of Fe^2 + to H2O2 was 0. 05, and the volume rate of H202 to water was about 2% with 3 hours reaction time and 1 hour sedimentation. Under abore conditions, the removal rate of COD can reach about 60% with excellent biodegradability.
What problem does this paper attempt to address?