Pretreatment of wastewater from fumaric acid production by extraction-Fenton oxidation process

WANG Hai-ling,NI Ke,ZHU Zhao-lian,SONG Yan,LIU Fu-qiang
DOI: https://doi.org/10.3969/j.issn.1009-2455.2012.01.005
2012-01-01
Abstract:Extraction-Fenton oxidation process was used to pretreat wastewater from fumaric acid production,the influences of extractant types,volume ratios of oil to water and extractant to thinner,pH value,temperature and some other factors on the extraction effect were investigated;besides,the further treatment of the wastewater after the extraction by Fenton oxidation process was also studied.The results showed that: with tributyl phosphate(TBP) as the extractant and isooctanol as the thinner,the optimal condition for the said kind of wastewater treat-ment was as follows: the volume ratio of oil to water was 0.8,the volume ratio of extractant to thinner was 3 ∶ 1,the pH value was the same as the initial pH value of the wastewater.The removal rate of CODCr by a single extraction could reach 73% under the above condition;the wastewater after the extraction was further treated by Fenton oxidation process,when the dosage of H2O2 was 9/5 Qth(theoretical dosage),the n(Fe2+) ∶ n(H2O2) was 1 ∶ 4,the pH value was 3,the reaction time was 1 h,the mass concentration of CODCr of the treated wastewater decreased to 1 000 mg/L,the total removal rate reached 96.5%.
What problem does this paper attempt to address?