Preliminary Studies on the Depth Selection of Seepage Calculation on the Infinite Deep Pervious Foundation

Mao Haitao,Shi Kebin,Gong Jingwei
DOI: https://doi.org/10.3969/j.issn.0559-9342.2009.04.015
2009-01-01
Abstract:"When the depth of pervious dam foundation is more than 1.5 times of the building’s impervious bottom length,such foundation can be considered as the infinite deep pervious foundation," such definition often makes designer difficult to select.This paper makes use of the conformal transformation method to get the effective depth of infinite deep pervious foundation.Meanwhile,for the permeability coefficient of layered infinite deep pervious foundation,this paper,based on the weights which every layer to subtractive the water head,calculates out its equivalent permeability coefficient.Compared to other methods,it is more conform with the actual situation.
What problem does this paper attempt to address?