A Method for Determining Critical Thickness of Base Soil of Foundation Pit Subjected to Confined Water

Wang Yu-lin,Xie Kang-he,Lu Meng-meng,Wang Kun
DOI: https://doi.org/10.3969/j.issn.1000-7598.2010.05.032
2010-01-01
Abstract:The change of pore water pressure and soil effective stress in foundation pit base, subjected to fast increase of confined water pressure due to sudden rise of the influent river during flood peak, have been analyzed. Based on soil permeability and its two damage mechanisms (i.e. tensile failure and shear failure), a new method for determining critical thickness of base plate of foundation pit is presented based on elastic theory. The new method is compared with traditional method to calculate the critical thickness of base soil of foundation pit by case study. Results show that the new method considering indices c(u), phi(u), and the size of foundation pit base, is more reasonable than the traditional method. However, the results calculated by the method in this paper reduce to the results by traditional method as for highly permeable soil like sand.
What problem does this paper attempt to address?