Shaking table test of damping ratio of strengthening-adding-story isolation structures

Liu Xin,Liu Weiqing,Du Dongsheng
DOI: https://doi.org/10.3969/j.issn.1001-0505.2012.06.024
2012-01-01
Abstract:The damping ratio of a complex structure composed of masonry,concrete reinforced wall and isolation steel framework was studied by shaking table tests.First,three test models,five-story strengthening structure,strengthening-adding-story structure and strengthening-adding-story isolation structure,were set up.Then,the sweeping date of these three models were fitted by the eigensystem realization algorithm(ERA).The damping ratios of these test models were identified under the different levels of the ground motions and the variation of damping ratios with the increase of the ground motions were studied.The experimental results show that,with the increase of ground motions,the stiffness of the non-isolated structure decreases while the damping ratio of the structure increases.For the mid-story isolation structure,the damage of masonry accumulates gradually with the increase of ground motions,inducing the increase of the stiffness ratio between superstructure and substructure,the decrease of the first-order damping ratio and the increase of the second-order damping ratio of the structure.The development trends of the damping ratio of these three test models are accorded with the theoretical analysis.The experimental results provide basis and reference for choosing proper damping ratios for different structure systems with different materials.
What problem does this paper attempt to address?