Research on the pretreatment of semi-coking wastewater by Fenton oxidation combined with ammonia stripping

Lü Yongtao,Wang Lei,Chen Zhen,Sun Ting,Wu Hongya,Wang Tao,Wang Zhiying
DOI: https://doi.org/10.3969/j.issn.1005-829X.2010.11.016
2010-01-01
Abstract:The research on Fenton oxidation combined with ammonia stripping for semi-coking wastewater pretreatment has been studied.The influential factors and removal efficiencies of COD,chroma and ammonia-nitrogen are investigated.When the water sample volumn is 100 mL,the results show that the optimal conditions of Fenton oxidation are as follows: the dosage of H2O2 is 40 mL,n(H2O2)∶n(Fe2+)=20,and pH=6.Ammonia stripping technical conditions are: temperature=60 ℃,and pH=11.Under these conditions,the removal rates of COD,chroma and ammonia-nitrogen can reach 95.72%,95% and 88%,respectively.The biodegradability is improved by 4 to 5 times.
What problem does this paper attempt to address?