Performance Study of Regeneratively Cooled Arcjet

Wei Yanming,Tang Huangzai,Zhao Wenhua,Hou Lingyun,Liu Zhengyin
DOI: https://doi.org/10.3969/j.issn.1004-7182.2006.06.002
2006-01-01
Abstract:A new arcjet was designed with regenerative cooling.The structure of arcjet,experimental system,measurement system and the small thrust measurement system were introduced.The performance experiment of arcjet was made in vacuum chamber and argon was chosen as the propellant.The specific impulse of arcjet is about 1 372~1 764 m/s.The specific impulse decreases with the increasing of flow rate and increases with the increasing of power.The efficiency of the arcjet is about 30%~57% and it increases with the increasing of flow rate and decrease with the increasing of power.
What problem does this paper attempt to address?