Quick start-up of external circulation (EC) anaerobic reactor

HAN Hong-jun,WANG Wei,AO Kai
2010-01-01
Abstract:The performance efficiency,stability and inner sludge distribution were investigated in the operation of the full-scale EC reactor for brewing wastewater treatment and the key factor to the formation of anaerobic granular sludge was analyzed,which provides the references for the start-up and operation of EC reactor.After operation for 95 d,the influent organic load and removal efficiency were 8.5 kg/(m3·d) and 80% respectively,and the effluent COD was lower than 400 mg/L.Meantime,the granular sludge with size of 0.5-1.0 mm was observed from the heights of 1.2 and 4 m in the EC reactor.The results demonstrate that EC anaerobic reactor using the intermittent-continuous start-up mode for treating the low COD concentration and high flow of brewing wastewater is feasible and the upflow velocity in range of 2.5-5 m/h is helpful to form granular sludge quickly.The experiment validates that the EC anaerobic reactor can start up stably and efficiently in the brewing wastewater treatment.