WAVEFRONT ANALYSIS AND CONTRAST SENSITIVITY OF ACRYSOF TORIC AND SPHERICAL INTRAOCULAR LENSES

XU Li,LIU Yi-zhi,ZHENG Dan-ying
2010-01-01
Abstract:Objective:To compare visual performance,total and high order wavefront aberrations,and contrast sensitivity in eyes with preexisting corneal astigmatism implanted with a single-piece foldable toric intraocular lens(IOL)(Acrysof toric IOL) and a single-piece foldable spherical(nontoric) IOL(SA60AT).Methods:Thirty one eyes of 25 patients who underwent phacoemulsification and Acrysof toric IOL implantation were included in the study.As a comparison,30 eyes of 22 patients meeting the same preoperative criteria for degree of corneal cylinder were enrolled to a SA60AT IOL implanted.The data for two groups was analysed prospectively.Outcomes of LogMAR vision(naked,with spherical corrected and with best corrected),refractive and corneal astigmatism,contrast sensitivity test and wavefront aberration test at early postoperative(1wk) and long-term(3mo) follow-ups were evaluated.Results:At last follow-up,all patients achieved LogMAR 0.3(20/40) or better naked vision in group,while 86.7% achieved in the control group.The mean postoperative refractive cylinder was 0.44±0.24D in observed group and 1.44±0.30D in the control group.Contrast sensitivity and high order aberration showed significantly better results in the study group than the control group.Conclusion:Phacoemulsification and Acrysof toric IOL implantation is an effective surgical option to correcting preexisting astigmatism in cataract surgery.The Acrysof toric IOL showed better functional visual results compared with the traditional spherical IOL.
What problem does this paper attempt to address?