Clinical Application and Evaluation of Toric Intraocular Lens

REN Pei-fang,LU Hong,SHEN Ye,LOU Ding-hua
DOI: https://doi.org/10.3760/cma.j.issn.1006-4443.2010.08.011
2010-01-01
Abstract:Objective Objective To evaluate the clinical results and rotational stability of AcrySof Toric intraocular lens (IOLs), and the impact of three measurements of keratometry on the results of astigmatism correction. Methods This prospective study included 23 eyes of 20 patients having cataract surgery. The IOL was calculated randomly using the results of automatic refractor, corneal topography or IOL Mastor. Implantation of the toric IOL was performed. The uncorrected visual acuity (UCVA),best corrected visual acuity (BCVA), residual refractive cylinders, residual keratometry, and toric IOL axis were measured. And the differences of three measurements were analyzed. Results The UCVAs were 0.69±0.16 and BCVAs were 0.83±0.15 at 3 months follow-up. The mean refractive cylinder decreased significantly after surgery from 3.23 D to 0.59 D. The pre-surgical and post-surgical keratometry and corneal astigmatism showed no statistical difference. By analyzing the differrence from the post-surgical to the aimed residual astigmatism, there was no significant difference among these three measurements. Conclusions The results indicate that AcrySof toric IOL showed good clinical results and rotational stability. Automatic measurements of keratometry have no significant impact on its correction of astigmatism.
What problem does this paper attempt to address?