Study on the factors influencing the treatment of urea wastewater by using the two-stage biological aerated filter

Ren Yuan,Yan Lilong,Ma Fang
DOI: https://doi.org/10.3969/j.issn.1005-829X.2010.11.014
2010-01-01
Abstract:The biological aerated filter(BAF) has been utilized for treating the chemical condensate wastewater with high urea concentration in a petrochemical plant.The effects of the factors such as urea volume load,ammonia-nitrogen concentration volume load,pH and height of BAF on urea removal efficiency are investigated.The results show that it is feasible to treat highly concentrated urea wastewater by using BAF.When the average urea volume load,ammonium load are 6.92,0-3 kg/(m3·d) and pH 7.0-11.0,respectively,urea removal efficiencies of the two-stage BAF are all above 85%.