Effects of Temperature and Ammonia Loading on Nitrification in Biological Aerated Filter for Advanced Treatment of Secondary Effluent of Wastewater

WANG Shu-tao,MA Jun,TIAN Hai
DOI: https://doi.org/10.3321/j.issn:0253-4320.2006.z2.055
2006-01-01
Abstract:The effects of temperature and ammonia loading on nitrification was investigated in combination of pre-ozonation with biological aerated filter(BAF) process,which was used to treat the secondary effluent of the domestic wastewater.The results show that the increasing of temperature results in the increasing of NH_3-N removal rate.20℃ can be considered as a critical temperature point,because the removal rate would increases only by 10% or so when the temperature rise from 20℃ to 28℃.The NH_3-N removal efficiency decreases with the NH_3-N loading increasing from 0.257 kg/(m~3·d) to 0.514 kg/(m~3·d) and to 1.029 kg/(m~3·d) at 20℃.Because the disslved oxygen is partially limitated,the nitrite can accumulate in 1.0 m at the stuffing layer at various temperatures.