Study on the effect of organic removal and ammonia nitrogen nitrified by biological aerated filter

Wang Lili,Hu Yongyou
DOI: https://doi.org/10.3969/j.issn.1001-3865.2006.04.006
2006-01-01
Abstract:The biological aerated filter(BAF) with granular media had been adopted on the actual lower concentrated domestic sewage treatment.They were studied for the influencing factors of hydraulic loading,organic and ammonia nitrogen loading on the performances of organic removal and ammonia nitrogen nitrified by BAF with stable gas to liquid ratio.The results showed that when COD in influent was between(105.8)~156.6 mg/L,the gas to liquid ratio was 3∶1 and the optimum hydraulic loading on degradation of organic compound was between 1.35~1.68(m~3/(m~2·h)),the average COD removal efficiency was about 86.3%.The direct affected factor of nitrification was ammonia nitrogen loading.Under the conditions of hydraulic loading and COD average value in influent were 1.05 m~3/(m~2·h) and 106.1 mg/L respectively,the maximum loading of ammonia nitrogen for the reactor was about 0.5 kg/(m~3·d),which the concentration of ammonia nitrogen in effluent was less than 15(mg/L).And then the kinetic model of the reactor was established accordingly.