Biological phosphorus and nitrogen removal in low C/N ratio domestic sewage treatment by a A~2/O-BAF combined system
CHEN Yongzhi,PENG Yongzhen,WANG Jianhua,ZHANG Liangchang
2010-01-01
Abstract:The behavior of biological phosphorus (P) and nitrogen (N) removal in a lab-scaled anaerobic/anoxic/oxic (A2/O)-biological aerated filter (BAF) combined system were investigated during the treatment of real domestic sewage with low C/N ratio.In order to solve the conflict of sludge retention time (SRT)between nitrifiers and polyphosphate-accumulating organisms(PAOs),a short SRT was applied in the A2/O reactor to wash out the nitrifiers.Therefore,in the system,the A2/O reactor was mainly used for P removal and denitrification and the BAF reactor was used for nitrification.The experimental results clearly showed that COD,N and P can be simultaneously removed in this combined system.When the C/N ratio was 4.2 and the internal recycle ratio was 250%,the concentrations of COD,total nitrogen (TN) and total phosphorus(TP)were reduced from 239.9 mg·L-1,57.3 mg·L-1 and 5.1 mg·L-1 in the raw waste water to 34.1 mg·L-1,13.3 mg·L-1 and 0.1 mg·L-1 in the effluent,respectively.The removal efficiencies of COD,TN and TP reached to 85.8%,76.9% and 98.3%,respectively.In addition,almost 100% ammonium nitrogen removal efficiency was achieved in the BAF reactor.Batch tests showed that the population of denitrifying phosphate-accumulating organisms (DPAOs) was up to 40.5% of the total PAOs.
What problem does this paper attempt to address?