Acute Damage of Lymphatic Vessel of Rat by High Intensity Focused Ultrasound:Experimental Study

马明,汪芳,孙庭
DOI: https://doi.org/10.3969/j.issn.1009-8194.2008.12.005
2008-01-01
Abstract:Objective To investigate the acute damage of lymphatic vessel of rats and the precaution of lymphatic metastasis by high intensity focused ultrasound(HIFU).Methods According to the different observational time,the rats were randomly divided into 24 h group(n=8) and 72 h group(n=8).The right inguinal region of 16 rats were irradiated using HIFU at electric power of 300 W 15 minutes for each target area.Animals were killed within 24 h and 72 h after irradiation and the pathological changes of target areas and the surrounding tissues were observed.Results HIFU penetrated the skin and precisely damaged lymphatic vessels.Compared to control side,the lymphatic vessels of target areas appeared rupture,deformation and lumens coarctation,and the tissues appeared hyperemia,edema and ischemic necrosis in the acute stage.The endodermis of lymphatic vessels was stained brown using immunohistochemical method.The changes of two groups had no significant difference between them.Conclusion HIFU could induce acute damage of lymphatic vessels.Therefore,it may decrease the possibility of lymphatic metastasis.
What problem does this paper attempt to address?