Physical Calculation for an X -Band Hybrid Dielectric-Iris-loaded Accelerator

He Xiao-Dong,Wu Cong-Feng,Feng Guang-Yao,Dung Sai,Pei Yuan-Ji
DOI: https://doi.org/10.1088/1674-1137/33/s2/028
2009-01-01
Abstract:A small, high performance X-band hybrid dielectric-iris-loaded travelling-wave linac with the length of 1.47 m and the maximum accelerating gradient of 45 MV/m has been designed. The beam energy of 33 MeV, the energy spread of 0.5%, the beam emittance of about 5.7 πmm·mrad and the capture efficiency of 40% are reached by adjusting the sizes of the accelerating cavities and the phase velocity. The attenuation per unit length of structure, the shunt impedance Rs, the quality factor Q, the group velocity and the phase velocity are also presented.
What problem does this paper attempt to address?