[Combined MBR-RO Process Treating High Strength Wastewater].

Fei-Fei Zhou,Han-Min Zhang,Zhi-Min Fu,Feng-Lin Yang
DOI: https://doi.org/10.3321/j.issn:0250-3301.2009.06.020
2009-01-01
Abstract:The performances of A/O-MBR/RO system for the removal of nitrogen and COD were investigated. Result indicated that most organic was removed in the A/O-MBR and the average removal efficiency was 95.6%. The water quality of RO effluent which in terms of TOC < 0.9 mg x L(-1), TN < 12.65 mg x L(-1), total rigidity < 0.038 mol x L(-1), total alkalinity < 14.6 mg x L(-1) could meet the water quality requirements for the town wastewater reuse. The average removal efficiency of organic was almost unaffected by COD/N, but the process of TN removal was affected by COD/N. TN removal was primarily based on simultaneous nitrification and denitrification (SND) process occurred in the aerobic zone and the average removal efficiency of TN was 89.4% with average COD/N of 10.2. Both aerobic SND and conventional biological nitrification/denitrification contributed to nitrogen removal, the average removal efficiency of TN was 72%, 74% with average COD/N of 7.1 and 5.6. The fouling cake layer formed on the RO membrane surface was observed by scanning electric microscopy. The membrane fouling was characterized by Fourier transform infrared spectroscopy technique which showed that the major components of the foulants were soluble microbe products.