Analysis of CO_2 Heat Pump Drying Operating Condition

王帅,欧阳晶莹,吴宇,谢英柏
DOI: https://doi.org/10.3969/j.issn.1004-7948.2012.10.006
2012-01-01
Abstract:Based on the analysis of the thermodynamic characteristics of CO2 transcritical cycle,a simulation analysis was made for the CO2 heat pump drying system by using the EES software.The results show that the COP and SMER of the system are growing with the increase of the evaporating temperature,while the exhausting temperature goes down.The COP and SMER of the system go down with the increase of the exhausting pressure,and the exhausting temperature of the compressor rises.Therefore,in order to keep the heat pump drying system works normally,we should keep the operating parameters of system are maintained within the following:the evaporating temperature should be under the highest evaporating temperature;when the drying process functions normally and meets the demand of the exhausting temperature of the compressor,the exhausting pressure should go down to the greatest extent.