Abstract:The first observation of a surface reconstruction with an atomic force microscope (AFM) is reported. The Au(111) p×√3(p∼22–30) surface under electrochemical potential control has been studied. Values for the periodicities and corrugation of the reconstruction that are similar to those found with a scanning tunneling microscope (STM) are obtained. This is an important test of instrumental artifacts owing to the high electric field and uncontrolled contact force in the STM. The STM consistantly yields higher resolution of the reconstruction, although both techniques also consistantly show an ‘‘atomic’’ lattice at high magnification. This apparent contradiction suggests that the atomic resolution in the AFM may be caused by atomic-scale periodicity in the tip–substrate interaction rather than by true single atom contact. This cannot be explained by tip geometry because the corrugation of the p×√3 reconstruction is much less (∼0.15 Å) than the height of a single atomic step on the Au(111) surface.