Design of High Voltage Unit in Particle Detector in Space

于向前,陈鸿飞,邹积清,施伟红
DOI: https://doi.org/10.3969/j.issn.0258-0934.2008.03.020
2008-01-01
Abstract:A kind of High Voltage Unit(HVU) is designed by using SG1525,which is used to provide the bias voltage to the solid detectors in particle measurement in space.The parameters of the transformer are obtained base on experiments and the best working point of HVU is calculated by the theoretical analysis and numerical simulation,such as the best pulse-width,working frequency and the primary loops of the transformer.In the design of HVU of this paper,the specifications are: output voltage-90V,pulse-space rate 6.2%,0~18μA load regulation 5.5‰,voltage regulation 1.3,ripple coefficient less than 5,and power dissipation 426 mW.The theoretical analysis and numerical simulation are agreed to the experiments,so that this method can be a useful reference for such HVU design.
What problem does this paper attempt to address?