Design of Bias Supply Based On Charge Pump In Space Particle Radiation Monitor

Xiang-qian YU,Hong-fei CHEN,Hong ZOU,Wei-hong SHI,Ji-qing ZOU,Wei-ying ZHONG
DOI: https://doi.org/10.3969/j.issn.0258-0934.2014.09.015
2014-01-01
Abstract:Based on charge pump as booster circle ,a transformer-less DC-DC converter was designed in order to produce a bias supply of -40 V for detector in space particle radiation monitor in some special situation .The square wave is produced by oscillator circle for 12VDC.The required voltage is produced by charge pump from square wave .The output voltage is stabilized by adjusting the input voltage .Based on the output voltage from the comparator which can reflect the charge of the output voltage of the converter , the transistor can adjust the input voltage .Based on the performance , the converter could be used as power supply for detector in space par -ticle radiation monitor .