Identification of failed cells inside PEMFC stacks in two cases: Anode/cathode crossover and anode/cooling compartment leak

Guangyu Tian,Sébastien Wasterlain,Denis Candusso,Fabien Harel,Daniel Hissel,Xavier François
DOI: https://doi.org/10.1016/j.ijhydene.2009.05.015
IF: 7.2
2010-01-01
International Journal of Hydrogen Energy
Abstract:Various PEMFC operating conditions can lead to irreversible damages as membrane break and gasket deterioration. If leak check procedures can highlight the lack of tightness in fuel cells, they are not appropriate to inform actually where the fault has occurred in the stacks. Thus, diagnosis procedures allowing the failed cells to be identified are needed. Then, these cells can be removed and replaced by safe ones. The article presents some descriptions of aged assemblies subjected to anode/cathode crossover and anode/cooling compartment leakage. Some experimental investigations are carried out with the goal to locate the defective cells. The open current voltages of the cells are monitored and analysed in different operating conditions. Experimental procedures combined with data analysis tools allow the detection of the failed cells, which show abnormal performance and voltage pattern when they are compared to the other safe cells.
What problem does this paper attempt to address?