On-line failure diagnosis and auto-disposal for automotive PEMFC

Pei Pucheng,Chao Pengxiang,Yuan Xing
DOI: https://doi.org/10.3772/j.issn.1002-0470.2009.12.015
2009-01-01
Abstract:An on-line method to diagnose failure of proton exchange membrane fuel cells (PEMFC) for vehicles was studied to resolve the failure of water flooding or membrane dehydration caused by the improper water and thermal managements. An experimental study was conducted to observe PEMFC's parameter variation, and the phenomena that hydrogen pressure drop was remarkably higher than normal during water flooding and the value of ohm resistance was considerably increased during membrane dehydration were found. Based on this, an on-line diagnostic method to avoid water flooding and membrane dehydration through thermal management was established, so that the reliability of PEM fuel cells can be enhanced when they in operation.