Study of Membrane Fouling Control Methods to Immersed Ultrafiltration Operation

孙丽华,李星,杨艳玲,孙文鹏,李圭白
DOI: https://doi.org/10.3969/j.issn.1672-0946.2009.06.007
2009-01-01
Abstract:The control methods of membrane fouling to immersed ultrafiltration used to treat surface water is investigated by pilot study. The effect of running and operation conditions such as aeration,backwashing,sewage discharge and chemical cleaning to control membrane fouling are reviewed by the change of running pressure. The results show that too high or too low aeration intensity could make the membrane running pressure increase rapidly. The appropriate aeration intensity is 45 m3/(m2·h)in the experiment. Backwashing with aeration and water at the same time could make the running pressure recover better than with water alone. And the water backwashing intensity has optimum value is 60 L/(m2·h). The resistance resulted from polarization and membrane aperture adsorption is a majority of membrane resistance. And immersed membrane need backwashing and sewage discharging regularly. Chemical cleaning with alkali (NaOH+NaClO) could make the running pressure recover successful. And the organisms in water are the main reason of membrane fouling.