Membrane Cleaning and Fouling Control in a Pilot Plant of Ultrafiltration for Drinking Water Treatment

ZHU Dan,GU Ping,WANG Haiyan,HE Fenghua,HAN Tao
DOI: https://doi.org/10.3969/j.issn.1007-8924.2012.04.016
2012-01-01
Abstract:A pilot-scale low pressure ultrafiltration membrane system was used to treat the finished water from a sedimention tank in the waterworks,and the membrane fouling control was investigated.Physical backwashing,chemical enhanced backwash(CEB),chemical cleaning and pre-chlorination were studied for membrane fouling control.The results show that the physical backwashing has a little effect on fouling control,however,CEB,an online cleaning mode could have a great effect on fouling control,and the average recovery rate of specific flux(Js) was 85%.The effect of chemical cleaning with oxalic acid was better,after cleaning,the average Js value was increased to 265 L/(m2·h· 0.1 MPa).Pre-chlorination could slow down the fouling rate.In addition,the composition of the effluent was analysed.The results revealed that the iron and dissolved organic matters were the major factors for fouling.
What problem does this paper attempt to address?