Design and Preparation of Black-Nickel Film on the Radiometer Chip

Li Ya-Nan,Liang Zhong-Zhu,Liang Jing-Qiu,Zheng Na,Fang Wei,Wang Wei-Biao,Yu Bing-Xi
DOI: https://doi.org/10.7498/aps.59.4530
IF: 0.906
2010-01-01
Acta Physica Sinica
Abstract:The black-nickel film on the flat type radiometer chip was investigated, and a black-nickel film which can be applied in this chip was prepared using electroplating method. The analyses of absorption of radiometer chip indicated that the absorption rate of the chip is proportional to the surface roughness. The black-nickel film was prepared and tested, and surface morphology testing showed that this film has microstructures of the scale 50 nm—1.5 μm. Infrared absorption measurement indicated that the absorptivity of the film in the 1.4—8 μm range is higher than 0.989. This high absorptivity black-nickel film improves the performance of the chip.
What problem does this paper attempt to address?