Design and Practice of Routes of Phlebotomizing from PICC Catheters

CHEN Xiang-yu,YUAN Ling,TAO Li-fang,YE Ming-zhi,LI Rong-mei
DOI: https://doi.org/10.3969/j.issn.1008-9993.2006.11.005
2006-01-01
Abstract:Objective To reduce the suffering from repeating punctures required by frequent blood sample collection during the treatment for oncology patients;and to minimize the interference when drawing blood samples from PICC(peripherally inserted central catheter).Methods 82 patients were randomly divided into 3 groups.Blood of 1 ml,2 ml,and 2.5 ml was abandoned respectively from PICC catheters.The complete blood count and biochemistry of blood samples were compared with the blood samples draw from routine peripheral veins at the same time.Results Taking blood sample through reasonable routes from PICC catheters,there was a difference among the 3 groups(P0.05).But the difference was within the laboratory permitted discrepancy according to CLIA'88 of US.Conclusion It is practical to take blood samples through reasonable routes from PICC catheters to check the complete blood count and biochemistry.It is recommended to choose different abandoned blood volumes based on the different requirements of accuracy of test results.
What problem does this paper attempt to address?