"Unbending Drill Collar" What Went Wrong?
Han Zhiyong
DOI: https://doi.org/10.3969/j.issn.1001-0890.2010.06.001
2010-01-01
Abstract:The three models given by reference were discussed in detail.The "soft-string and tube model" is right principally.While "the model of inside tube borne hydraulic pressure" and "the model of inside tube with a central tube borne hydraulic pressure" were wrong theoretically.The experimental data of "the model of inside tube borne hydraulic pressure" from reference[3] were analyzed.It shows that the maximum axial load is less than critical buckling load,therefore the conclusion from its laboratory tests is wrong.Because "the model of inside tube borne hydraulic pressure" is wrong theoretically,the 5 well field application mentioned in reference[3] can not prove the "unbending drill collar".
What problem does this paper attempt to address?