Effect of Chemical Phosphorus Removal Ratio on Nitrogen and Phosphorus Removal from Low Carbon Municipal Wastewater

HUANG Jian,TANG Li-hua,TANG Yu-chao,WU Chang-nian,WANG Jian
DOI: https://doi.org/10.3969/j.issn.1000-4602.2012.03.024
2012-01-01
Abstract:Side-stream A2O process was developed to improve the ability of nitrogen and phosphorus removal from low carbon municipal wastewater and the phosphorus recovery.The nitrogen and phosphorus removal and phosphorus recovery were studied by pumping different amounts of phosphorus-rich supernatant in the end of anaerobic tank into chemical phosphorus removal tank.Under the conditions of the influent COD of 136 to 168 mg/L,NH3-N of 32 to 40 mg/L,TN of 36 to 45 mg/L,TP of 6 to 8 mg/L and no additional carbon source,the removal rates of TN and TP were 95.7% and 84% when the chemical phosphorus removal ratio(ratio of phosphorus-rich supernatant amount to influent amount) was 10% to 20%.The effluent TP concentration was lower than 0.5 mg/L at the chemical phosphorus removal ratio of 15%.The effluent quality could reach the first criteria class A specified in Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant(GB 18918-2002).In addition,the amount of phosphorus recovery was 23% to 29% of the influent phosphorus,thus achieving phosphorus sustainable development and increasing the economic benefit of WWTP.