Study on Advanced Phosphorus Removal in A/O Unit of Integrated Process for Reclamation of Municipal Sewage

HAO Wei-dong,LI Dong,WU Di,MA Jin-ming,ZHANG Jie
DOI: https://doi.org/10.19853/j.zgjsps.1000-4602.2011.19.003
2011-01-01
Abstract:The A/O process,as the first treatment unit of the integrated process for reclamation of municipal sewage,can achieve advanced removal of phosphorus and COD as well as provide appropriate influent for the follow-up autotrophic denitrification units through adjusting the relevant operating parameters. The effluent TP is less than 1 mg/L,both nitrate and nitrite are less than 5 mg/L,and the average ammonia nitrogen is 68.44 mg/L under the conditions of 20℃,TP of 6 to 8 mg/L,COD of 300 to 500 mg/L,ammonia nitrogen of 70 to 90 mg/L,nitrite of 0.015 to 0.25 mg/L and nitrate of 0.4 to 1.7 mg/L in the influent.The average removal rate of TP is 90%with 17%ammonia nitrogen loss.The system achieves advanced removal of phosphorus and COD while inhibiting nitrification by controlling DO at 0.6 to 0.8 mg/L in aeration tank.