Abstract:In order to deal with the problem that the high total phosphorus (TP) concentration of effluent from one municipal wastewater treatment plant in Beijing,using the biological process(A2O) followed with chemical phosphorus removal process,laboratory tests and technical scale experiments were conducted in order. The aerobic tank effluent was sampled for evaluating the phosphorus removal efficiency of PAC, PFS, FeCl3 respectively, and the phosphorus removal mechanisms of the three reagents were further discussed. Phosphorus removal efficiency of PAC was the best among three coagulants. The TP concentration of effluent could be lower than 0.5mg/L and the coagulant cost was 0.078Yuan/t with the dosage of 60mg/L and the coefficientβof 4.15. The aerobic tank outlet was selected to be the dosing position for the technical scale experiments. Results showed that demand in phosphorus removal efficiency could be met with a PAC dosage of 60mg/L and coefficientβof 4.15. Considering the water quality and loading fluctuation, in order to ensure TP concentration of effluent discharged lower than 0.5mg/L, a detailed optimization scheme was proposed, through taking effective measures of improving the biological phosphorus removal and dosing the coagulants with feedback control methods to decrease the dosage amount of PAC,therefore reduced the operation cost and chemical sludge amount.