The Sensitivity and Radiation Dose in Pulmonary Nodules (Early-Stage Lung Cancer) Screening in Healthy Population: Longitudinal Comparison of GE VCT and GE 750 HDCT

WANG Er-nuo,GAO Feng,WANG Yuan-yuan,LI Ming,REN Qing-guo,TANG Ping,HUA Yan-qing
2013-01-01
Abstract:Objective To compare the value of GE VCT with GE 750 HDCT in pulmonary nodules(early lung cancer) screening in healthy population.Methods Based on the analysis of lung CT and clinical data of 3 269 healthy individuals,the sensitivity and radiation dose of GE VCT and GE 750 HDCT in detection of early lung cancer were compared.All the hardwares,softwares and scan parameters were the same except the detectors and reconstruction algorithms.Results In GE VCT group(931 cases),72 cases were detected with pulmonary nodules,and 3 cases were pathologically confirmed early-stage lung cancer.In GE 750 HDCT group(605 cases),83 cases were detected with pulmonary nodules,and 4 cases were pathologically confirmed early-stage lung cancer.The detection rate of GE 750 HDCT was higher than GE VCT(P0.05).The average radiation dose in GE VCT group was(9.820 9±1.630 92) mGy,while in GE 750 HDCT was(5.425 0±1.721 08) mGy.There was significant difference between them(P0.05).Conclusion The resolution of GE 750 HDCT is higher than GE VCT,but the radiation dose is lower.GE 750 HDCT is more suitable for early lung cancer screening in healthy population.