Design and optimization of a temperature controller with low overshoot, fast respond and high COP based on water-source thermoelectric heat pump

Wei Zhu,Dong Chen,Jianwei Shi,Jingshuang Zhang,Huadong Zhao,Cheng Li
DOI: https://doi.org/10.1016/j.applthermaleng.2024.122473
IF: 6.4
2024-01-22
Applied Thermal Engineering
Abstract:In this study, a thermoelectric temperature control device combined with liquid heat transfer with accuracy up to ±0.06 °C was designed and constructed. The heating and temperature control performance of the device were evaluated by 3 key parameters Overshoot( σ ), Respond time( Ts ) and Coefficient of performance for heating ( COPh ). By establishing response surface models, the critical factors that influence the 3 key parameters are addressed. The results indicate that water temperature ( Tw ) is the most significant factor that influencing σ and COPh . The current intensity ( I ) is the primary factor that influencing Ts . By using a particle swarm optimization algorithm, the overall performance of the device is optimized.
energy & fuels,engineering, mechanical,thermodynamics,mechanics
What problem does this paper attempt to address?