Study on the spatial and temporal distribution of the bed density in an air dense medium fluidized bed (ADMFB) based on the electrical capacitance tomography (ECT) measurement system

Guofeng Li,Xibo Liu,Chenlong Duan,Qingxia Liu,Yuemin Zhao,Rajender Gupta
DOI: https://doi.org/10.1016/j.powtec.2021.08.026
IF: 5.64
2021-11-01
Powder Technology
Abstract:In this study, the ECT system was used to study the temporal and spatial distribution characteristics of bed density in an ADMFB under the influence of superficial gas velocity and static bed height. The results show that, In the axial distribution, the closer to the top of the bed at low gas velocity(<11.5 cm/s), the higher the density, and the closer to the top at high gas velocity (> 13 cm/s), the lower the density. In the radial distribution, the closer to the central axis, the lower the density. With the decrease of static bed height, the radial uniformity becomes worse. The optimal gas velocity is 12.5 cm/s, under which the bed spatial distribution is the most uniform, and the ecart probable moyen of spherical particles is 0.06. The separation density is smaller than the bed density and is close to the central axis density.
engineering, chemical
What problem does this paper attempt to address?