Effective Concrete Failure Area for SC Structures Using Stud and Tie Bar Under Performance Tests

Yeongun Kim,Byong J. Choi
DOI: https://doi.org/10.3390/ma17215381
IF: 3.4
2024-11-05
Materials
Abstract:Nuclear power plants, where steel-plate concrete (SC) structures are commonly adopted, require large-scale components to withstand significant loads, such as those caused by sudden explosions. As a result, SC modular members used in nuclear power plants must have thicker walls filled with concrete compared to standard-sized ones. These large walls also require additional components, such as tie bars and H-shaped steel sections, to reinforce adhesion and resist shear stresses. This study focuses on tie bars placed adjacent to studs and evaluates their influence on the tensile strength of wall structures. To investigate this, we conducted experimental tests using full-scale specimens, including various combinations ranging from single stud to combined stud-tie configurations. Based on the results of these performance tests, we propose a design recommendation for estimating the tensile capacity of SC structures, considering the influence of tie bars.
materials science, multidisciplinary,chemistry, physical,physics, applied, condensed matter,metallurgy & metallurgical engineering
What problem does this paper attempt to address?