Stress corrosion tests for prestressing steels—Part 1: The influence of surface condition and test solution composition on hydrogen charging

Lando Seifert,Andreas Grunewald,Thoralf Müller,Gino Ebell
DOI: https://doi.org/10.1002/maco.202313948
2024-04-17
Materials and Corrosion
Abstract:Stress corrosion tests, according to ISO 15630‐3, are mandatory in approvals and continuous surveillance of prestressing steels. This experimental paper deals with the technical problem of high scattering of the stress corrosion test results and focuses on the test parameters solution composition, surface condition, and temperature in electrochemical measurements. Tests for assessing prestressing steels' susceptibility to hydrogen‐induced stress corrosion cracking are essential for approvals, in‐house monitoring, and third‐party material testing. According to ISO 15630‐3, the time to brittle fracture by constant load under corrosive conditions in thiocyanate test solutions (A or B) at 50°C is measured. In the literature, a high scattering in stress corrosion tests is reported, which questions the integrity of the test procedure. This paper shows the results of studies about the influence of solution composition on hydrogen charging in electrochemical and permeation measurements. Electrochemical experiments show that polished steel surfaces without common drawing layers have more consistent free corrosion currents, polarization resistances, and B‐values in solution A with low scattering compared to the solution B experiments. The influence of temperature at 50°C and an ambient temperature of 22°C was also tested.
materials science, multidisciplinary,metallurgy & metallurgical engineering
What problem does this paper attempt to address?